Probable maximum flood for Watana and Devil Canyon sites /

The estimated probable maximum floods at the sites of the proposed Watana and Devil Canyon dams have been analyzed for the purpose of designing spillways and other facilities. This study is part of the planning for the Susitna Hydroelectric Project. Contains weather observations and data on streamfl...

Full description

Saved in:
Bibliographic Details
Alternate Title:Susitna Hydroelectric Project. Probable maximum flood for Watana and Devil Canyon sites
Corporate Contributor(s):HARZA-EBASCO Susitna Joint Venture.

Alaska Power Authority.
Publisher:Alaska Power Authority,
Report Numbers:APA 457
Series:Document (Susitna Hydroelectric Project) ; no. 457.
Subjects:
Online Access:Link to Full Text
Library Holdings:Print Versions
Description
Summary:The estimated probable maximum floods at the sites of the proposed Watana and Devil Canyon dams have been analyzed for the purpose of designing spillways and other facilities. This study is part of the planning for the Susitna Hydroelectric Project. Contains weather observations and data on streamflow, historical floods for the region, and snow.
Physical Description:168 p. in various paging : ill., maps, charts ; 28 cm.
Notes:At head of title: Susitna Hydroelectric Project.

"Federal Energy Regulatory Commission. Project no. 7114."--Cover.

"January 1984."
Report Type:Draft report.
Bibliography:Includes bibliographical references.